Rebe's Fibre Optic DTS Temperature Monitoring System serves industrial plant substations and distribution rooms, and is what plant teams searching for cable tunnel temperature monitoring end up deploying. It continuously acquires distance-temperature profiles from a fibre optic DTS device, maps fibre distance onto real cable assets, and returns temperature health verdicts that are explainable, actionable and auditable.
Need product specifications, use cases or references?
Call +86 130 4890 6506 for selection guidance and comparable project types Email usInside industrial plant substations and distribution rooms, 0.4 kV high-current main cables, critical-load feeders, parallel cable groups and dense cable tunnels run under sustained load. The recurring failure modes are:
This is the case for continuous coverage rather than a set of point sensors — including the cases where point sensors are the better answer, which the same page sets out.
A DTS device — distributed temperature sensing, where the fibre cable itself is the sensor — already produces a distance–temperature curve, within the limits of its spatial resolution. What operators actually lack is an answer to five questions:
Is there an anomaly right now? Where is it? How severe is it? What is the evidence? What should I do next?
Most installations leave those five questions to the operator, reading a raw curve. The result is predictable: threshold alarms fire constantly, operators stop trusting them, and when an incident happens there is no retained evidence to reconstruct it.
| Common outcome | This system |
|---|---|
| Raw distance-temperature curve handed to the operator | Five-level health verdict with the evidence attached |
| Distance in metres ("62 °C at 1,243 m") | Distance mapped to a real asset — building, distribution room, feeder, cable section, core |
| Alarm noise; operators mute it | One hotspot = one alarm. Acknowledge does not clear; silencing does not stop recording |
| "Normal" shown when data is missing | "Cannot determine" is an explicit verdict — the system never reports "no anomaly" when data is insufficient |
| Thresholds guessed; conclusions unexplained | Every verdict carries object, time, location, temperature, trend, hotspot, data quality, coverage, limitations and a recommended action |
| No evidence after an incident | Immutable evidence bundles, retained up to 3 years |
| Role | What they get |
|---|---|
| Substation / distribution room O&M | Which feeder, which cable, how severe, what to do — without reading a curve |
| Cable tunnel operators | Continuous coverage of dense tunnels and parallel cable groups that manual patrols cannot cover |
| Plant energy & safety management | Early hotspot detection plus a retained, auditable evidence trail |
Applications: industrial plant substations and distribution rooms · underground cable tunnels and utility corridors · parallel cable groups · critical-load feeders.
A note on scope. This is a monitoring and decision-support system. It does not trip breakers, shed load, or execute any switching operation — see section 4.4. If you need automatic protection and tripping, that belongs to your protection relays, not to this system.
| Verdict | Meaning |
|---|---|
| No anomaly found | Data, coverage, mapping and policy all satisfy the conditions for judgement, and no anomaly was seen |
| Attention advised | A trend or deviation worth watching |
| Anomaly present | A confirmed anomaly |
| Serious anomaly | Requires priority handling |
| Cannot determine | Data, coverage, mapping or policy is insufficient — the system does not fall back to "no anomaly" |
This last row is the point. Reporting "normal" because you could not measure is the single most damaging thing a monitoring system can do. Rebe's design rule is: when the data is insufficient, say so.
Fibre distance is mapped onto the real asset hierarchy: plant → distribution room → feeder → line section → physical cable → cable core → parallel cable group.
Two separations are maintained deliberately:
This is what allows a verdict to say which cable rather than which metre.
These are capability boundaries, stated because they are part of the value:
The basic temperature monitoring function runs in full without any current data. When current data is available, load-correlated enhancement is enabled. This means a site can start with temperature only and add current correlation later, without replacing the system.
After a Windows restart, acquisition and platform access are designed to recover within 10 minutes without anyone logging in (a design target — see the specification table).
We can provide: selection guidance · integration and network design guidance · product documentation on request
Call +86 130 4890 6506 for selection guidance and comparable project types Email usTell us your site conditions and what the data needs to connect to — we reply within one business day.
⚠️ Every figure in this table is a design target, not a measured result. They describe what the system is engineered to do. For what the resolution and sampling figures mean — and why they are not the same thing — see the glossary entry.
| Metric | Design target |
|---|---|
| Channels per device | 4 |
| Points per channel | ~25,000 |
| Scan cycle | 5 seconds |
| End-to-end verdict latency | ≤ 10 seconds |
| Loss-of-communication detection | ≤ 15 seconds |
| Recovery after Windows restart | ≤ 10 minutes, unattended |
| Host recommendation | Windows host · 8 cores · 32 GB RAM · 1 TB SSD minimum |
A single Docker Compose stack (modular monolith + PostgreSQL 16 + MinIO) on Windows with Hyper-V.
Unlike the design targets above, this is a real, recorded result.
The system has completed a read-only field integration with a fibre optic DTS device. All four channels returned complete temperature profiles.
In one stable acquisition: point spacing 0.20 m, 507 temperature points in a single frame, temperature range 30.4–32.8 °C (mean 31.67 °C).
The evidence is fixed with SHA-256 checksums.
| Item | Detail |
|---|---|
| What you receive | The temperature monitoring software platform (licensed) plus integration into your DTS device and your asset model |
| Form of delivery | Software deployment on a Windows host you provide, plus engineering configuration |
| Prerequisites | A fibre optic DTS device accessible over Modbus TCP; the fibre installation and its as-built routing |
| Integration work | Mapping fibre distance to your asset hierarchy; policy definition; alarm routing |
| What we need from you | Cable schedule and as-built routing, distribution room layout, DTS device model and register map, current-transformer availability |
Commercial note. Because this system is a software platform plus integration rather than a boxed instrument, pricing is quoted per project — software licence plus engineering days. Ask us for a scope-based quotation.
Not necessarily — and that is usually the point. If you already have a fibre optic DTS device that exposes a Modbus interface, the system is designed to integrate with it as a read-only client, so you do not have to replace the sensing hardware to gain the interpretation, asset mapping, alarm governance and evidence-retention layers. If the sensing side is faulty, that is a separate matter and has to be addressed on its own.
Yes. Basic temperature monitoring runs in full without current data. When current data becomes available, load-correlated enhancement is enabled. Note the deliberate boundary: without current data the system will not assert overload or connection fault as a confirmed cause.
The system returns "Cannot determine" rather than "no anomaly found". Loss of communication is detected within 15 seconds (design target). The absence of data is surfaced as a data-quality condition, not silently smoothed away.
No. A hotspot persisting across many scans creates a single business alarm. Condition state and handling state are tracked separately, and silencing an alarm does not clear it or stop recording.
No. It does not trip breakers, interrupt power or shed load. High-risk operations are denied by default. The system's role is monitoring and decision support; switching remains with your protection and control systems and your operating procedures.
This page does not state those figures, and that is deliberate. They are determined by the DTS device and the fibre installation, not by the platform — the platform expresses and propagates what the device provides, and does not inflate capability according to sampling density. Actual values should be confirmed against your device datasheet and site fibre conditions during scoping.
Per-frame profiles for 7 days, minute-level profiles for 1 year, and assessment and alarm evidence for 3 years. Evidence bundles are immutable. Backup must be off-box.
Acquisition and platform access are designed to recover within 10 minutes of a Windows restart, without anyone logging in — a design target, not a measured result.
Yes — ask us for a walkthrough of the online demonstration, and tell us your distribution room or tunnel scale and what you are trying to detect. We will show you the parts relevant to your scenario rather than a generic tour.
To scope this for your site, we need three things: your distribution room or tunnel layout, the DTS device you have or plan to use, and the asset hierarchy you report against.
Call +86 130 4890 6506 — we will tell you whether your fibre installation can support this, and what the mapping would look like.